  Datasheet File OCR Text:
  diesel engine-g enerator set 350-xs6d t3 350 ekw / 60 hz / standby 208 - 600v a tognum g roup brand // epa tier 3 certifed // engine-generator set tested to iso 8528-5 for t ransient r esponse // ul2200, csa listing ofered // accepts rated load in one step per nfpa 110, level 1 // all engine-generator sets are prototype and factory tested // mtu onsite energy is a single source supplier // global product support // 2 year standard warranty // series 60 (6063hv35) diesel engine - 14.0 liter displacement - electronic unit pump injection - 4-cycle // complete range of accessories // permanent magnet generator (pmg) - optional - brushless, rotating field - 300% short circuit capability - 2/3 pitch windings // digital control panel(s) - ul recognized, , nfpa 110 - complete system metering - lcd display // cooling system - integral set-mounted - engine driven fan f acts s ystem r atings standby voltage (l-l) 208v** 240v** 480v** 600v** phase 3 3 3 3 pf 0.8 0.8 0.8 0.8 hz 60 60 60 60 kw 350 350 350 350 kva 437.5 437.5 437.5 437.5 amps 1214 1052 526 421 skva@30% voltage dip 765 765 1020 1100 generator model 433csl6216 433csl6216 433csl6216 433psl6248 temp rise 130c/27c 130c/27c 130c/27c 125c/40c connection 12 lead low wye 12 lead hi delta 12 lead hi wye 4 lead wye ** ul2200 ofered
2 /// / 350-xs6 dt3 // engine air cleaner oil pump full flow oil filter jacket water pump closed crankcase vent thermostats exhaust manifold C dry blower fan & fan drive radiator - unit mounted electric starting motor - 24v governor C electric isochronous base - formed steel sae flywheel & bell housing charging alternator - 24v battery box & cables flexible fuel connectors flexible exhaust connection epa certifed engine // g enerator nema mg1, ieee and ansi standards compliance for temperature rise and motor starting sustained short circuit current of up to 300% of the rated current for up to 10 seconds self-ventilated and drip-proof superior voltage waveform digital, solid state, volts-per-hertz regulator no load to full load regulation brushless alternator with brushless pilot exciter 4 pole, rotating field 130c standby temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing .25% voltage regulation 100% of rated load - one step 3% maximum harmonic content // d igital control p anel(s) digital metering engine parameters generator protection functions engine protection sae j1939 engine ecu communications windows-based software multilingual capability remote communications to our rdp-110 remote annunciator 16 programmable contact inputs 7 contact outputs ul recognized, , ce approved event recording ip 54 front panel rating with integrated gasket nfpa110 level compatible // additional features oil drain extension & s/o valve flexible fuel connector battery cables vibration isolation pads jacket water heater: -20 f mainline circuit breaker ul2200 listed steel sub-base radiator duct flange (opu) lube oil & antifreeze operators and owners manual 2 year/3000 hour warranty factory tested at 0.8 pf (3 ph) // o ptional features battery charger: 6 amp or 10 amp battery: 24 volt w/ rack circuit breaker: standard or 100% mufer (opu only) sub-base fuel tank w/ electrical stub-up area weatherproof enclosure sound attenuation - 1 1/2 foam - sound scoops remote annunciator isochronous governor stan d ard equipment
3 /// / 350-xs6 dt3 // engine manufacturer mtu detroit diesel model series 60 (6063hv35) type 4-cycle arrangement 6-inline displacement: cu in (lit) 855 (14) bore: in (cm) 5.24 (13.3) stroke: in (cm) 6.61 (16.8) compression ratio 16:1 rated rpm 1,800 engine governor ddec max power: standby: bhp (kwm) 550 (410) regulation .25% frequency 60 hz air cleaner dry // liquid capacity (lubrication) total oil system: gal (lit) 9.5 (36) engine jacket water capacity: gal (lit) 6 (23) system coolant capacity: gal (lit) 42 (159) // electrical electric volts dc 24 cold cranking amps under 0f (-17.8c) 950 // fuel system fuel supply connection size 1/2 npt fuel return connection size 1/2 npt maximum fuel lift: ft (m) 6.7 (2.1) recommended fuel diesel #2 total fuel flow: gal/hr (lit/hr) 86.9 (329) // fuel consumption at 100% of power rating: gal/hr (lit/hr) 27 (102) at 75% of power rating: gal/hr( lit/hr) 21.4 (81) at 50% of power rating: gal/hr (lit/hr) 14.6 (55) // cooling - r adiator system ambient capacity of radiator: f (c) 122 (50) max. restriction of cooling air, intake, and discharge side of rad.: in. h 2 0 (kpa) 0.5 (0.12) water pump capacity: gpm (lit/min) 96 (363) heat rejection to coolant: btum (kw) 7,450 (131) heat radiated to air to air: btum (kw) 4,900 (86) heat radiated to ambient: btum (kw) 5,223 (92) // air r equirements aspirating: *scfm (m 3 /min) 1,160 (32.8) air flow required for rad. cooled unit: *scfm (m 3 /min) 18,422 (522) air flow required for heat exchanger/remote rad. based on 25f rise: *scfm (m 3 /min) 11,779 (336) * air density = 0.0739 lbm/ft 3 (1.184 kg/m 3 ) // exhaust system gas temp. (stack): f (c) 963 (517) gas volume at stack temp: cfm (m 3 /min) 3,090 (87.5) maximum allowable back pressure: in. h 2 0 (kpa) 40.8 (10.16) app lication d ata
4 /// / 350-xs6 dt3 ? mtu onsite energy. subject to alteration due to technological advances. 2009-05 emissions d ata no x + nmhc co pm 2.62 0.87 0.14 all units are in g/hp-hr and are e p a d 2 cycle values. emission levels of the engine may vary as a function of ambi - ent temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. the data provided are laboratory results from one engine representing this rating. the data was obtained under cont - rolled environmental conditions with calibrated instrumentation traceable to the united states national bureau of standards and in compliance with us epa regulations found within 40 cfr part 89. the weighted cycle value from each engine is guaran - teed to be below the us epa standards at the us epa defned conditions. r ating definitions and conditions // ambient capability factor at 984 ft (300 m). consult your local mtu onsite energy power generation distributor for other altitudes. // standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capa - bility for this rating. ratings are in accordance with iso-3046/1, bs 5514, as 2789, and din 6271. // deration factor: altitude : 1% per 1,000 ft (305 m) above 600 ft (183 m). t emperature : 1% per 10f (5.5c) above 77f (25c). w eights and dimensions sound d ata u nit t ype standby full load standby n o load opu w/critical grade mufer (dba) 95.5 89 sound attenuated enclosure (dba) 87.5 81 materials and specifcations subject to change without notice. // t ognum g roup companies: europe / m iddle east / africa / latin america / mtu onsite energy / 88040 friedrichshafen / germany / phone + 49 7541 90 7060 / fax +49 7541 90 7084 / powergenregion1@mtu-online.com // asia / australia / pacifc / mtu onsite energy / 1, benoi place / singapore 629923 / republic of singapore / phone + 65 6861 5922 / fax + 65 6861 3615 / powergenregion2@mtu-online.com // u sa / canada / m exico / mtu onsite energy / 100 power drive / mankato, minnesota 56001 / usa / phone + 1 507 625 7973 / fax + 1 507 625 2968 / powergenregion3@mtu-online.com // worldwide for hot module / mtu onsite energy / 81663 munich / germany / phone + 49 89 203042 800 / fax +49 89 203042 900 / info@mtu-online.com // www.mtu-online.com weights and dimensions are based on open power units and are estimates only. consult the factory for accurate weights and dimensions for your specifc generator set. measurements for sound data are taken at 23 ft (7 m). system dimensions (l x w x h) height w/t ank 24hr. weight (less tank) opu 150 x 68 x 90.5 in (3,810 x 1,730 x 2,300 mm) 118.5 in (3,010 mm) 7,284 lb (3,304 kg) epu 150 x 68 x 106.5 in (3,810 x 1,730 x 2,710 mm) 134.5 in (3,420 mm) 8,741 lb (3,965 kg) drawing above for illustration purposes only, based on standard open power 480 volt generator. lengths may vary with other voltages. do not use for installation design.


▲Up To Search▲   

 
Price & Availability of 350-XS6DT3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X